MECER UPS 3000KVA

KSh 39,000.00

In stock

  • Capacity: 3000VA/1800W
  • Input/output Voltage: 110/120 VAC or 220/230/240 VAC
  • Battery: 12 V/9 Ah x 2
  • Line interactive UPS
  • Microprocessor control guarantees high reliability
  • Boost and buck AVR for voltage stabilization
  • Auto restart while AC is recovering
  • Simulated sine wave
  • Off-mode charging
  • Cold start function
  • USB communication port and RJ-11/RJ-45 protection
  • Overload, discharge, and overcharge protection
  • Supports Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, and MAC
“ME-3000-VU (Vesta 3000)” MECER 3000VA(1800W) (with AVR, Monitoring Software + Cable & Built-in Surge Protection) -Serial and USB standard 9 x12V 7Ah batteries

Mecer 3000-VA (1800w) Line Interactive UPS from Netways

  • Buy Mecer 3000-VA (1800w) Line Interactive UPS with Microprocessor control guarantees high reliability,
  • Boost and buck AVR for voltage stabilization
  • Auto restart while AC is recovering
  • Simulated sine wave
  • Off-mode charging
  • Cold start function
  • USB communication port and RJ-11/RJ-45 protectionMecer 2000-VA (1200w) Line Interactive UPS
  • Overload, discharge, and overcharge protection
  • Supports Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, and MAC

Capacity
3000 VA / 1800 W

Input
Voltage
110/120 VAC or 220/230/240 VAC

Voltage Range
81-145 VAC  /  162-290 VAC

Frequency Range
60-50 Hz (auto sensing)

Output
Output Voltage
110/120 VAC or 220/230/240 VAC

AC Voltage Regulation (Batt. Mode)
±10%

Frequency Range (Batt. Mode)
60 Hz or 50 Hz  ±1 Hz

Transfer Time
Typical 2-6ms, 10ms max

Waveform (Batt. Mode)
Simulated Sine Wave

Battery
Battery Type & Number
12 V/9 AH x 4

Mecer 3000-VA (1800w) Line Interactive UPS

Typical Recharge Time
4-6 hours recover to 90% capacity

Indicators
AC Mode
Green Lighting

Battery Mode
Yellow Flashing

Fault
Red lighting

Protection
Full Protection
Overload, discharge and over charge protection

Alarm
Battery Mode
Sounding every 10 seconds

Low Battery
Sounding every second

Overload
Sounding every 0.5 seconds

Battery Replacement Alarm
Sounding every 2 seconds

Mecer 3000-VA (1800w) Line Interactive UPS

Fault
Continuously Sounding

Physical
Dimensions, D X W X H(mm)
495  x 150 x 250

Net Weight (kgs)
24.8

Operating Environment
Humidity
0-90 % RH @ 0- 40° (non-condensing)

Noise Level
Less than 40dB

Management
Optional USB/RS-232 Port
Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC

Mecer 3000-VA (1800w) Line Interactive UPS

Mecer 3000-VA (1800w) Line Interactive UPS

Mecer 3000-VA (1800w) Line Interactive UPS (with AVR, Monitoring Software + Cable & Built-in Surge Protection) -Serial and USB standard 9 x12V 7Ah batteries

Buy Mecer 3KVA Line Interactive UPS ME 3000 VU from Dayari Technologies.

  • Buy  Mecer 3KVA Line Interactive UPS ME 3000 VU with Microprocessor control guarantees high reliability,
  • Boost and buck AVR for voltage stabilization
  • Auto restart while AC is recovering
  • Simulated sine wave
  • Off-mode charging
  • Cold start function
  • USB communication port and RJ-11/RJ-45 protection
  • Overload, discharge, and overcharge protection
  • Supports Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, and MAC
Mecer 3000-VA (1800w) Line Interactive UPS specifications
SKU ME-3000-WPTU
WEIGHT 27.600
PHYSICAL DIMENSIONS 421 x 190 x 318 (mm)
CAPACITY 3000 VA / 2400 W
VOLTAGE RANGE LOW LINE TRANSFER 160VAC/140VAC/120VAC/110VAC±5% ( based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)
VOLTAGE RANGE LOW LINE COMEBACK 168VAC/148VAC/128VAC/118VAC ± 5 % ( based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)
VOLTAGE RANGE HIGH LINE TRANSFER 300 VAC ± 5 %
VOLTAGE RANGE HIGH LINE COMEBACK 290 VAC ± 5 %
FREQUENCY RANGE 40Hz ~ 70 Hz
PHASE Single phase with ground
POWER FACTOR ≧ 0.99 @ nominal voltage (input voltage)
OUTPUT VOLTAGE 200/208/220/230/240VAC
AC VOLTAGE REGULATION (BATT. MODE) ±1% (Batt. Mode)
FREQUENCY RANGE (SYNCHRONIZED RANGE) 47 ~ 53 Hz or 57 ~ 63 Hz
FREQUENCY RANGE (BATT. MODE) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
OVERLOAD Sounding twice every second
CURRENT CREST RATIO 3:1
HARMONIC DISTORTION ≦ 3 % THD (linear load) ≦ 6 % THD (non-linear load)
WAVEFORM (BATT. MODE) Pure Sinewave
AC TO DC Zero
INVERTER TO BYPASS 4 ms (Typical)
AC MODE 90%
BATTERY MODE 88%
BATTERY TYPE 12 V / 9 AH
NUMBERS 6
RECHARGE TIME 4 hours recover to 90% capacity (Typical)
CHARGING CURRENT 1.0 A (max.)
CHARGING VOLTAGE 82.1 VDC ± 1%
BATTERY TYPE & NUMBERS No
CHARGING CURRENT No
CHARGING VOLTAGE No
HUMIDITY 20-90 % RH @ 0- 40°C (non-condensing)
NOISE LEVEL Less than 50dBA @ 1 Meter
OPTIONAL USB/RS-232 PORT Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC
OPTIONAL SNMP Power management from SNMP manager and web browser
Be the first to review “MECER UPS 3000KVA”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Main Menu